Possible malfunctions of the storage battery and ways of their elimination
|
Cause of defect
|
Way of elimination
|
The starter scrolls a cranked shaft of the engine with small speed
|
The battery is discharged below an admissible limit
|
To charge the battery, to check up the generator and a pressure regulator (the Generator> and <a pressure Regulator> see <)
|
Short circuit in one of elements
|
Element with short circuit to replace or repair
|
The raised power failure in a starter feed circuit
|
To clear battery conclusions, to tighten fastening of wires of a starter
|
The raised self-category of the battery
|
To clear a surface of covers of elements of a dirt and electrolit. The battery to charge
|
Destruction of lattices of positive plates
|
To replace the battery
|
Fast выкипание electrolits
|
The raised adjustable pressure
|
To check up a pressure regulator (the pressure Regulator> see <), to hand over in a workshop for adjustment
|
The pressure regulator is faulty
|
To replace a regulator
|
Vypleskivanie electrolits through a ventilating aperture
|
High level of electrolit
|
To establish normal level
|
The storage battery does not give pressure
|
Breakage of an element in the battery
|
Element with breakage to replace
|